Sentry Air Systems Ductless Fume Hood – Deluxe Hood Model
Quote
Sentry Air Systems ductless fume hoods are high-quality portable units that protect lab workers and samples. These units are designed for use in locations that do not have access to outside ventilation. Air is recirculated through high-efficiency air filters eliminating the need for external ducting or venting. The deluxe model hoods have additional features such as LED lighting, hour counter, pressure reader, and upgraded hinges.
Description
• Adjustable LED light
• Upgraded Hinges
• Variable speed controller
• Acrylic hood material
• Hour counter
• Pressure reading
• No costly ducting or venting
• No permitting issues for venting outside of the building (ie. EPA air sampling)
• Adaptable (mobility and ease in change of layout)
• Environmentally friendly
• Significant energy cost savings
Note: There are some low molecular weight substances that may not be appropriate for a ductless fume hood. In addition, certain high workload conditions may require external ducting.
• Hood Dimensions:
30” O.D.: 24″D x 32″W x 25″H , I.D.: 23.5″D x 30″W x 24″H
40” O.D: 24″D x 42″W x 25″H, I.D.: 23.5″D x 40″W x 24″H
50” O.D: 24″D x 52″W x 25″H, I.D.: 23.5″D x 50″W x 24″H
60” O.D: 24″D x 62″W x 25″H, I.D.: 23.5″D x 60″W x 24″H
70” O.D: 24″D x 72W” x 25″H, I.D.: 23.5″D x 70″W x 24″H
• Hood Material:
– Sides: .250″ White Acrylic
– Base: .500″ White High Density Polyethylene
– Top: .500″ Clear Polycarbonate
• Front Windows:
0.250″ Clear Polycarbonate
• Motor:
Fractional Horsepower
• Total Weight:
30” 40” Approx. 100 lbs.
50” Approx. 125 lbs.
60” Approx. 140 lbs.
70” Approx. 155 lbs
• Available Filter Efficiencies:
HEPA Filter – Up to 99.97% efficient on particles down to 0.3 microns
ASHRAE Filter – Up to 95% efficient on particles down to 0.5 microns
ULPA Filter – Up to 99.9995% efficient on particles down to 0.12 microns
Activated Carbon & Specialty-Blended Filters – Efficiency varies per chemical.
• Blower Dimensions:
13″ L x 13″ W x 14.5″ H
• Approximate Inlet Velocities:
Pre-filter & 99.97% HEPA Filter – 100 FPM
Pre-filter & Heavy-duty Carbon Filter – 60 FPM
• Electrical:
115/1/60, 2 amps
220/1/50, .75 amps (not on 30” model)
• Sound Level:
61 to 66 dba (Blower Speed: Low to High)
• Max Operating Temperature:
Not to exceed 170 degrees Fahrenheit
• Patented Design:
U.S. PATENT #5,843,197
Limited two-year warranty from date of shipment on defects due to materials or workmanship
Related products
Consolidated Medium Lab Series Steam Sterilizers Single Chamber 21.8 Cu. Ft.
Quote• An intuitive user interface with modern, easy to view touchscreen display.
• Ability to program up to 50 sterilization cycles.
• Ability to favorite frequently used cycles for quick access.
• A controller platform ...
Baker BioChemGARD® e3 Class II Type B2 Biological Safety Cabinet
Quote
Baker SterilGARD® e3 Class II Type A2 Biological Safety Cabinets
Quote• Industry’s most durable and reliable cabinet means lower life-cycle costs and years of trouble-free operation.
• Multiple energy-saving features equal sign...