Haier Ultralow -86C Freezer, Energy Star 338L (11.9 cf)
Quote
The Haier DW-86L338J ultralow freezer delivers reliable -86°C deep freeze storage in a 338L (11.9 cu. ft.) upright cabinet engineered for the demanding sample protection requirements of research laboratories, pharmaceutical and biopharmaceutical facilities, blood banks, biorepositories, and vivarium operations that require long-term preservation of plasma, serum, cell lines, enzymes, genomic specimens, and biological reagents at ultra-low temperatures.
Haier Biomedical’s proprietary hydrocarbon (HC) refrigeration system improves energy efficiency by 45% compared to conventional HFC-based ULT freezer designs, while vacuum insulation panels (VIP) combined with a foamed inner door and five-layer door seal gasket reduce heat gain by 25%, keeping stored samples protected during routine door access cycles — a critical performance factor in high-throughput laboratory environments and cold chain storage programs aligned with ISBER best practices and GLP or GMP sample management protocols.
The slim cabinet design maximizes usable storage space within the unit’s compact footprint, while the pressure equalization port allows the door to be reopened quickly after closing — reducing the workflow interruption common with conventional -80°C and -86°C freezers — and the microprocessor-controlled LED digital display, automatic clean-filter alarm, and sensor error alerts ensure operational visibility across all storage conditions; learn more about ARES Cool cold storage solutions and explore the full laboratory cold storage portfolio available through ARES Scientific.
Description
Haier DW-86L338J Ultralow -86°C Freezer – Product Highlights
- ENERGY STAR certified ultralow freezer with a hydrocarbon (HC) refrigeration system that delivers 45% greater energy efficiency than conventional HFC-based -86°C and -80°C freezer systems, reducing operating costs across long-term biorepository and laboratory cold storage programs.
- Vacuum insulation panel (VIP) technology combined with a foamed inner door and five-layer seal gasket reduces heat gain by 25%, maintaining stable temperature uniformity during repeated door access cycles critical to sample integrity in pharmaceutical and clinical research workflows.
- Pressure equalization port allows the freezer door to be reopened immediately after closing — eliminating the waiting period typical of sealed -86°C upright freezers and improving workflow efficiency in high-volume ULT upright freezer environments.
- Microprocessor-controlled LED digital display provides continuous temperature monitoring with malfunction alarms, automatic clean-filter alerts, and sensor error notifications to support uninterrupted sample protection and compliance documentation in GLP and GMP cold storage environments.
- Natural hydrocarbon (HC) refrigerant replaces HFC refrigerants with an environmentally responsible alternative that delivers improved energy-saving performance across the full operating range of the -86°C storage cabinet.
- Compatible with existing competitor racking systems, allowing laboratories to transition to the Haier DW-86L338J without replacing internal storage infrastructure — an important consideration for biobanks and research institutions managing large sample inventories across multiple freezer generations.
- Optional CO2 and LN2 backup systems are available for facilities requiring continuous sample protection during power interruptions, supporting compliance with ISBER best practices and institutional biorepository protocols for high-value biological specimen storage.
- Slim cabinet design maximizes available floor space in laboratory, pharmacy, and blood bank cold storage rooms without sacrificing 338L (11.9 cu. ft.) usable capacity, making it well-suited for space-constrained facilities that require full-scale ultra-low temperature storage.
- Optional RS232/485 port connectivity supports integration with laboratory data management systems and remote temperature monitoring platforms for facilities requiring networked cold storage oversight and 21 CFR Part 11-aligned audit trails.
- ARES Scientific is an authorized distributor for Haier Biomedical, ensuring genuine Haier products with full manufacturer warranty support — explore the complete Haier product line available through ARES Scientific.
Technical Specifications – Haier DW-86L338J Ultralow -86°C Freezer
| Model Number: | DW-86L338J |
| Temperature Range: | -40°C to -86°C |
| Capacity: | 338 L (11.9 cu. ft.) |
| Cabinet Type: | Upright |
| Refrigerant Type: | Natural hydrocarbon (HC) |
| Insulation Technology: | Vacuum insulation panels (VIP) |
| Door Seal: | Five-layer seal gasket with foamed inner door |
| Display: | LED digital display, microprocessor controlled |
| Alarms: | Malfunction alarm, automatic clean-filter alarm, sensor error alert |
| Connectivity (Optional): | RS232/485 port |
| Backup Systems (Optional): | CO2 backup system, LN2 backup system |
| Accessories (Optional): | Temperature recorder, storage racks, storage boxes |
| Racking Compatibility: | Compatible with existing competitor racking systems |
| Certification: | ENERGY STAR |
| Brand: | Haier Biomedical |
Frequently Asked Questions – Haier DW-86L338J Ultralow -86°C Freezer
What is a ULT freezer and what is the Haier DW-86L338J used for?
A ULT (ultra-low temperature) freezer maintains storage temperatures at or below -80°C, enabling long-term preservation of biological specimens including plasma, serum, cell lines, enzymes, genomic samples, and pharmaceutical compounds that degrade at conventional freezer temperatures; the Haier DW-86L338J is a 338L upright ULT freezer rated to -86°C, designed for use in research laboratories, biorepositories, blood banks, pharmaceutical facilities, and vivarium operations requiring sustained deep freeze storage.
What is the difference between a -80°C freezer and a -86°C freezer?
The primary distinction is minimum attainable temperature — a -86°C ultralow freezer like the Haier DW-86L338J reaches a lower minimum setpoint than a standard -80°C unit, providing additional thermal margin for critical sample types or facilities operating in warm ambient environments where the freezer works against higher room temperatures; both designations refer to the same class of ultra-low temperature laboratory freezer, and the DW-86L338J is designed to deliver stable, verifiable temperature performance across the full -40°C to -86°C operating range.
Is the Haier DW-86L338J ENERGY STAR certified?
Yes — the Haier DW-86L338J carries ENERGY STAR certification, reflecting its hydrocarbon (HC) refrigeration system that operates at 45% greater efficiency than conventional ULT freezer designs; for laboratories and institutions managing sustainability initiatives, energy reporting requirements, or facility compliance programs, the DW-86L338J’s certified efficiency profile supports both operational cost reduction and environmental impact goals across long-term laboratory cold storage deployments.
Does the Haier DW-86L338J require any special electrical or infrastructure installation?
Specific electrical requirements including voltage, amperage, and circuit specifications were not listed on the product page and should be confirmed directly with ARES Scientific prior to installation planning; the DW-86L338J is an upright cabinet model with a slim footprint intended for standard laboratory floor placement, and optional CO2 or LN2 backup systems will require additional infrastructure planning for gas supply lines if selected.
Is the Haier DW-86L338J compatible with existing freezer racking systems?
Yes — the DW-86L338J is designed with compatibility for existing racking systems from competitor manufacturers, allowing laboratories to transition to Haier ultralow storage without replacing internal storage infrastructure; optional Haier storage racks and storage boxes are also available for new installations, and the unit’s 338L (11.9 cu. ft.) upright interior accommodates standard biorepository racking configurations used across research and clinical ULT freezer programs.
What alarm and monitoring features does the Haier DW-86L338J include?
The DW-86L338J includes a malfunction alarm, automatic clean-filter alarm, and sensor error alert, all displayed through the microprocessor-controlled LED digital interface; an optional RS232/485 port supports connection to external laboratory data management and remote temperature monitoring systems for facilities requiring networked oversight, audit trail documentation, or integration with institutional cold storage compliance programs.