Description
SmartDrop L:
• Ideal for basic DNA/RNA/protein quantification and purity
• Affordable LED and silicon detector technology
• Fixed 0.5mm path length
• Detect up to 2500ng/µl of dsDNA
• Minimum sample size: 1.0-2.0µl
• Fast results in about 5 seconds
• Automatic 260/280 ratio calculation
SmartDrop X:
• Full-spectrum absorbance scans from 200 to 800nm
• Quickly calculates and displays 260/280 and 260/230 ratios
• Long-life Xenon lamp with precision monochromator
• Auto-ranging path lengths of 0.2mm and 1.0mm
• Detect up to 4,500 ng/µl of dsDNA without dilution
• Minimum sample size: 0.5-2.0µl
• Preset programs for BCA, Bradford, and Lowry assays
SmartDrop XF:
• Spectrophotometer and fluorometer combined
• Full-spectrum absorbance scanning and calculation of 260/280 and 260/230 ratios
• Long-life Xenon lamp with precision monochromator
• Auto-ranging path lengths of 0.05mm, 0.2mm, and 1.0mm
• Detect up to 15,000ng/µl of dsDNA without dilution
• Minimum sample size: 0.5-2.0µl
• Integrated fluorometer for sensitive quantitation of low concentration nucleic acids
• Blue light channel (460nm) for detection of dyes, GFP, and fluorescein; additional channels available upon request
SmartDrop L:
• Display: 7-inch touch screen
• Minimum sample size: 1.0-2.0µl
• Path length: 0.5mm
• Light source: UV LED
• Detector: UV Silicon Photocell
• Wavelength: 260, 280, & 600nm
• Absorbance range: 0.2 – 50 A (10mm equivalent)
• Absorbance precision: 0.005 A
• Lower limit of detection: dsDNA: 10ng/µl; BSA: 0.1 mg/ml
• Upper limit of detection: dsDNA: 2,500ng/µl; BSA: 75.0 mg/ml
• Detection time: < 6 seconds
• Communication ports: USB for data export
• Voltage input: DC 24V, 2A
• Power: 25W
• Dimensions (WxDxH): 20.8 x 8.0 x 18.6 cm / 8.2 x 11.0 x 7.3 in.
• Weight: 3.6 kg / 7.9 lbs
SmartDrop X:
• Display: 7-inch touch screen
• Minimum sample size: 0.5-2.0µl
• Path length: 0.2mm, 1.0mm
• Light source: Xenon Flash Lamp
• Detector: 2048 Element Linear Silicon CCD Array
• Wavelength: 200 – 800nm (1nm steps)
• Absorbance range: 0.04 – 90 A (10mm equivalent)
• Absorbance precision: 0.003 A
• Lower limit of detection: dsDNA: 2ng/µl; BSA: 0.1mg/ml
• Upper limit of detection: dsDNA: 4,500ng/µl; BSA: 135mg/ml
• Detection time: < 5 seconds
• Communication ports: USB for data export
• Voltage input: DC 24V, 2A
• Power: 25W
• Dimensions (WxDxH): 20.8 x 8.0 x 18.6 cm / 8.2 x 11.0 x 7.3 in.
• Weight: 2.8 kg / 6.2 lbs
SmartDrop XF:
• Display: 7-inch touch screen
• Minimum sample size: 0.5-2.0µl
• Path length: 0.05mm, 0.2mm, 1.0mm
• Light source: Xenon Flash Lamp
• Detector: 2048 Element Linear Silicon CCD Array
• Wavelength: 200 – 800nm (1nm steps)
• Absorbance range: 0.04 – 300 A (10mm equivalent)
• Absorbance precision: 0.003 A
• Lower limit of detection: dsDNA: 2ng/µl; BSA: 0.1mg/ml