E-Z Anesthesia® AD-5000 Digital Anesthesia System

Quote

The E-Z Anesthesia® AD-5000 Digital Anesthesia System is a next-generation solution designed for laboratories requiring highly accurate, low-flow rodent anesthesia systems for mice, rats, and other small animals. Built around the proven TEC 3 isoflurane vaporizer platform, the AD-5000 integrates advanced digital inhalation anesthesia control for consistent delivery, precise metering, and safer workflows in vivariums, animal research facilities, and surgical suites. Its flexible design makes it ideal for researchers seeking a reliable small-animal anesthesia machine with modern monitoring and automatic flow adjustments.

A high-resolution touch screen interface allows users to control flow rates to three independent outputs, supporting oxygen delivery from 0.5 to 2.5 LPM across an induction chamber and two nose-cone stations. This makes the AD-5000 an excellent option for multi-animal workflows, simultaneous preparation, or paired surgical procedures using a multi-station rodent anesthesia configuration. The system’s intelligent flow circuit automatically balances and adjusts delivery based on which stations are active, ensuring consistent and stable isoflurane concentrations at each output—eliminating manual recalibration or guesswork.

To support surgical and imaging procedures, the AD-5000 incorporates an elapsed timer for both the induction chamber and breathing circuits, enabling accurate anesthesia monitoring and standardized protocols. The system also includes digital warming beds, helping maintain physiological body temperature during surgery—an essential feature for reducing anesthetic depth fluctuations and improving recovery outcomes. Together, these features make the AD-5000 one of the most advanced digital rodent anesthesia systems available, delivering the precision, safety, and ease of use required for today’s small-animal research environments.

Description

E-Z Anesthesia® AD-5000 Digital Rodent Anesthesia System

The E-Z Anesthesia® AD-5000 Digital Anesthesia System is a next-generation solution designed for laboratories requiring highly accurate, low-flow rodent anesthesia systems for mice, rats, and other small animals. Built around the proven TEC 3 isoflurane vaporizer platform, the AD-5000 integrates advanced digital inhalation anesthesia control for consistent delivery, precise metering, and safer workflows in vivariums, animal research facilities, and surgical suites. Its flexible design makes it ideal for researchers seeking a reliable small-animal anesthesia machine with modern monitoring and automatic flow adjustments.

A high-resolution touch screen interface allows users to control flow rates to three independent outputs, supporting oxygen delivery from 0.5 to 2.5 LPM across an induction chamber and two nose-cone stations. This makes the AD-5000 an excellent option for multi-animal workflows, simultaneous preparation, or paired surgical procedures using a multi-station rodent anesthesia configuration. The system’s intelligent flow circuit automatically balances and adjusts delivery based on which stations are active, ensuring consistent and stable isoflurane concentrations at each output—eliminating manual recalibration or guesswork.

To support surgical and imaging procedures, the AD-5000 incorporates an elapsed timer for both the induction chamber and breathing circuits, enabling accurate anesthesia monitoring and standardized protocols. The system also includes digital warming beds, helping maintain physiological body temperature during surgery—an essential feature for reducing anesthetic depth fluctuations and improving recovery outcomes. Together, these features make the AD-5000 one of the most advanced digital rodent anesthesia systems available, delivering the precision, safety, and ease of use required for today’s small-animal research environments.

Key Benefits

  • Highly precise digital anesthesia delivery for mice, rats, and other small animals.
  • Supports multi-animal workflows with three independently controlled outputs.
  • Reduces waste anesthetic gas use through stable, low-flow digital control.
  • Improves animal safety and recovery with integrated digital warming beds.
  • Streamlines research workflows using built-in timers, flush controls, and guided menus.
  • Minimizes user error via automated flow balancing and digital safeguards.
  • Remote monitoring and low-tank alerts help prevent unexpected interruptions.
  • Turnkey design delivers a complete induction and maintenance anesthesia solution.

Features & Functions

  • Intuitive touch-screen display for fast access to system settings, flow controls, and warming bed temperature management.
  • Complete turnkey rodent anesthesia system with components for induction chambers and nose-cone stations.
  • Easy, plug-and-play setup ideal for busy vivariums and multi-user surgical suites.
  • User-friendly workflow design with guided menus that simplify operation for new and experienced technicians.
  • Integrated video tutorials for quick training, onboarding, and troubleshooting.
  • Digital control of up to three warming beds, ensuring consistent thermal support during procedures.
  • Individual temperature adjustment for each bed to meet specific mouse or rat surgical requirements.
  • Fahrenheit or Celsius selectable modes for flexible global operation.
  • Built-in temperature safety monitoring to prevent overheating and support animal welfare.
  • High-performance, all-brass isoflurane vaporizer based on the reliable TEC 3 design for stable anesthetic output.
  • Fully digital flow-rate control for precise delivery to each breathing circuit and the induction chamber.
  • Effortless on-screen flow adjustments from 0.5 to 2.5 LPM for low-flow rodent anesthesia applications.
  • Independent timers for each breathing circuit supporting accurate, reproducible anesthesia durations.
  • Chamber flush button for rapid clearance of anesthetic gas between animals and improved workflow efficiency.
  • Optional gas tank monitoring module for real-time visibility of oxygen supply levels.
  • Low-tank email alerts to prevent unexpected interruptions during procedures.
  • Remote access capability for monitoring system status or making adjustments away from the unit.
  • “All Done” one-touch shutdown that safely powers down all active components and circuits.
  • Multiple language options to support international and multilingual facilities.
  • 0.5–2.5 LPM flow range optimized for mouse, rat, and small-animal inhalation anesthesia.
  • Integrated carry handle enabling safe, easy transport throughout the vivarium or surgical area.

Why Choose the E-Z Anesthesia® AD-5000?

The AD-5000 delivers best-in-class precision for small-animal inhalation anesthesia by combining the proven performance of a TEC 3 vaporizer with advanced digital flow control. Designed specifically for rodent research and vivarium workflows, it provides stable, low-flow delivery to an induction chamber and up to two breathing stations—automatically balancing gases as outputs are activated or disabled.

With a modern touch-screen interface, integrated warming beds, real-time timers, and optional oxygen tank monitoring, the AD-5000 gives researchers everything needed for standardized, repeatable, and safe anesthesia. Whether preparing animals for imaging, survival surgery, necropsy, or brief procedural sedation, the AD-5000 provides exceptional control while reducing training time and user error.

Digital safeguards, temperature monitoring, multiple language support, and remote access make it one of the most user-friendly and globally compatible rodent anesthesia systems available. Its compact footprint and carry handle also allow easy movement between rooms—ideal for multi-suite vivariums or core surgical spaces.

Technical Specifications

Vaporizer Type TEC 3 style isoflurane vaporizer (all brass)
Flow Range 0.5 – 2.5 LPM
Outputs 1 induction chamber + 2 breathing circuits
Flow Control Fully digital, automatic balancing between active outputs
Temperature Support Three independent digital warming beds
Temperature Units Selectable °F or °C
Timers Independent timers for each breathing circuit and induction chamber
Display Full-color touch-screen interface
Safety Features Temperature monitoring, digital safeguards, chamber flush mode
Connectivity Optional remote access
Gas Monitoring Optional oxygen tank monitoring module
Alerts Low-tank email notifications (with monitoring option)
Languages Multiple language support
Mobility Integrated carry handle for easy transport
Power / Shutdown Digital control system with “All Done” one-touch full shutdown

AD-5000 Base System Includes

  • Digital anesthesia vaporizer machine with TEC 3–style isoflurane control.
  • Oxygen or medical air regulator for precise carrier-gas delivery.
  • (1) EZ-178 Rodent Induction Chamber for safe and controlled isoflurane induction.
  • (1) HB-163XL Heated Chamber Warmer to maintain animal temperature during induction.
  • (2) Heated surgery beds with breathers (flat or V-shaped) optimized for mouse and rat procedures.
  • (1) Case of ReFresh charcoal filters (8) for passive waste anesthetic gas scavenging.
  • Complete mouse and rat nose cone set with plugs and all required connecting tubing.

Technical Specifications

  • Anesthetic Agent: Isoflurane 0–5% (rodent inhalation anesthesia)
  • Carrier Gas: Oxygen or medical air
  • Flow Range: 0.5–2.5 LPM per output
  • Flow Adjustment: 0.25 LPM digital increments
  • Number of Outputs: 3 (induction chamber + two breathing circuits)
  • Input Voltage: 120/240 VAC, 1.6 amp, 50/60 Hz
  • Minimum Gas Supply Pressure: 15 psi
No information available, please contact us for information