2.5 Cu. Ft. ARES Cool Plus Series Freestanding Countertop Glass Door Laboratory Refrigerator
Quote
The ARS-HC-UCFS-0204G is a 2.5 cu. ft. ARES Cool freestanding countertop laboratory refrigerator with a right-hinged glass swing door, sized for mid-volume cold storage in pharmacies, clinical laboratories, vivariums, and retail settings where at-a-glance inventory visibility reduces door-open time and improves cold-chain integrity.
This Plus Series glass-door compact laboratory refrigerator extends the ARES Scientific laboratory and pharmacy refrigerator portfolio with microprocessor-controlled cycle temperatures between 1°C and 10°C, forced-draft air circulation, audible and visual high and low temperature alarms with remote alarm contacts, and a keyed door lock — backed by UL/C-UL listing and ENERGY STAR certification for CDC-aligned vaccine storage workflows.
Pharmacy buyers and clinical lab managers evaluating glass-door undercounter pharmacy refrigerators, transparent-door vaccine storage units, mid-capacity biomedical refrigerators with visibility, or at-a-glance inventory cold storage for high-turnover environments will find the UCFS-0204G’s glass door reduces unnecessary door openings while four adjustable shelves organize 2.5 cubic feet of working inventory.
Description
ARS-HC-UCFS-0204G – Product Highlights
- ARES Cool proprietary cold storage line, distributed exclusively by ARES Scientific with full warranty support for institutional purchasers across the pharmacy and laboratory refrigerator category.
- Glass swing door for at-a-glance inventory visibility reduces unnecessary door openings, supports faster visual inventory checks, and preserves cold-chain integrity in high-throughput pharmacy and clinical workflows.
- Microprocessor temperature controller with digital display manages cycle temperatures between 1°C and 10°C, bracketing the CDC vaccine storage range with precision unavailable from mechanical thermostat designs.
- Forced-draft air circulation delivers excellent temperature uniformity throughout the cabinet and rapid recovery after door openings — particularly valuable in high-traffic pharmacy environments.
- Audible and visual high and low temperature alarms with remote alarm contacts integrate with facility BMS or local monitoring stations; a 3/4-inch probe access port accommodates third-party NIST-traceable data loggers.
- Four adjustable interior shelves and LED interior lighting organize 2.5 cubic feet of storage and support visibility for routine pharmacy and laboratory inventory management.
- Right-hinged glass swing door with keyed lock balances visibility with sample security and access control documentation requirements in clinical and pharmacy settings — see our vaccine refrigerator selection guide for cold-chain best practices.
- HFC-free R600a hydrocarbon refrigerant meets sustainability targets and reduces global warming potential versus legacy HFC formulations.
- UL/C-UL listed and ENERGY STAR certified documents electrical safety compliance and qualifies the unit for institutional energy-efficiency rebate and procurement standardization programs.
- Two-year parts and labor warranty plus five-year compressor parts warranty; freestanding chassis requires 4 inches of clearance on back and sides for ventilation and warranty compliance.
Frequently Asked Questions – ARS-HC-UCFS-0204G
What is the ARS-HC-UCFS-0204G and how does the glass door affect performance?
The UCFS-0204G is the glass-door variant of the 2.5 cu. ft. ARES Cool Plus Series freestanding countertop laboratory refrigerator. The glass door provides at-a-glance inventory visibility, reducing the number and duration of door openings — a practical benefit for high-throughput pharmacy and clinical workflows. The tradeoff is marginally lower insulation versus the solid-door UCFS-0204, generally offset by reduced cold-air loss from fewer door openings.
When should I choose a glass door over a solid door for vaccine or medication storage?
Glass doors suit pharmacy refrigerators with frequent visual inventory checks, dispensing-room placement where staff need quick stock visibility, and clinical settings where reducing door-open time matters more than maximum insulation. Solid doors better protect light-sensitive contents (certain vaccines like Varicella, some reagents, photoactive medications) — verify the product’s storage requirements before choosing. The CDC Vaccine Storage and Handling Toolkit and our selection guide cover this tradeoff in depth.
Does the UCFS-0204G support CDC vaccine storage requirements?
The microprocessor controller maintains cycle temperatures from 1°C to 10°C, bracketing the 2°C to 8°C CDC vaccine storage window. The unit includes audible and visual alarms plus a probe access port for adding a NIST-traceable data logger or temperature monitoring device — standard CDC requirements. Verify that any light-sensitive products in inventory tolerate glass-door storage; some vaccines explicitly require solid-door units.
What applications use a glass-door undercounter refrigerator?
Common applications include retail and outpatient pharmacy vaccine storage where staff verify inventory visually multiple times per day, reagent storage in research laboratories with frequent retrieval, point-of-use medication storage in clinic exam rooms, and dispensing-room cold storage in hospital pharmacies — anywhere visual inventory verification adds workflow value.
What is the temperature uniformity inside the UCFS-0204G?
Forced-draft air circulation using an interior fan distributes air throughout the cabinet, delivering excellent temperature uniformity and rapid recovery after door openings — performance characteristics that distinguish laboratory and pharmacy refrigerators from household refrigerators that use simpler airflow designs. Exact uniformity figures depend on load configuration and ambient conditions; facility validation testing characterizes specific installations.
Can the glass door be locked?
Yes — the unit ships with a keyed door lock that secures the glass door identically to the solid-door variant, supporting access control documentation for pharmacy and clinical compliance audits under CDC, USP, CAP, CLIA, and institutional QA programs.
Technical Specifications – ARS-HC-UCFS-0204G
| SKU: | ARS-HC-UCFS-0204G |
| Storage Capacity: | 2.5 cu. ft. |
| Door: | 1 glass swing door, right hinged |
| Shelves: | Four adjustable shelves |
| Mounting and Installation: | Leveling legs |
| Interior Lighting: | LED interior light |
| Airflow Management: | Forced draft air circulation |
| External Probe Access: | Probe access port (3/4 in.) |
| Insulation: | Foamed-in-place EPA-compliant high-density urethane foam |
| Exterior Materials: | White powder-coated steel |
| Access Control: | Keyed door lock |
| Refrigerant: | HFC-free R600a |
| Defrost: | Cycle defrost |
| Controller Technology: | Microprocessor temperature controller |
| Display Technology: | Digital temperature display |
| Adjustable Cycle Temperature: | 1°C to 10°C |
| External Alarm Connection: | Remote alarm contacts |
| Alarms: | Audible and visual high and low temperature alarms |
| Rated Amperage: | 0.9 A |
| Power Plug/Cord: | NEMA 5-15, conforms to UL 471 |
| Facility Electrical Requirement: | 115 VAC / 60 Hz / 1 PH |
| Agency Listing: | UL/C-UL listed, ENERGY STAR certified |
| Exterior Dimensions (W × D × H): | 17.75 in. × 19.5 in. × 28.875 in. |
| Interior Dimensions (W × D × H): | 14.25 in. × 13.25 in. × 23.25 in. |
| Door Swing: | 15.5 in. |
| Total Open Depth: | 35 in. |
| Product Weight: | 68 lbs |
| Shipping Weight: | 97 lbs |
| General Warranty: | Two (2) year parts and labor |
| Compressor Warranty: | Five (5) year compressor parts |
| Operating Environment: | Indoor use, +18°C to +26°C (+65°F to +78°F), <70% RH |
| Installation Note: | Freestanding (UCFS) requires 4 in. clearance on back and sides |