2.5 Cu. Ft. ARES Cool Plus Series Freestanding Countertop Glass Door Laboratory Refrigerator

Quote

The ARS-HC-UCFS-0204G is a 2.5 cu. ft. ARES Cool freestanding countertop laboratory refrigerator with a right-hinged glass swing door, sized for mid-volume cold storage in pharmacies, clinical laboratories, vivariums, and retail settings where at-a-glance inventory visibility reduces door-open time and improves cold-chain integrity.

This Plus Series glass-door compact laboratory refrigerator extends the ARES Scientific laboratory and pharmacy refrigerator portfolio with microprocessor-controlled cycle temperatures between 1°C and 10°C, forced-draft air circulation, audible and visual high and low temperature alarms with remote alarm contacts, and a keyed door lock — backed by UL/C-UL listing and ENERGY STAR certification for CDC-aligned vaccine storage workflows.

Pharmacy buyers and clinical lab managers evaluating glass-door undercounter pharmacy refrigerators, transparent-door vaccine storage units, mid-capacity biomedical refrigerators with visibility, or at-a-glance inventory cold storage for high-turnover environments will find the UCFS-0204G’s glass door reduces unnecessary door openings while four adjustable shelves organize 2.5 cubic feet of working inventory.

Description

ARS-HC-UCFS-0204G – Product Highlights

  • ARES Cool proprietary cold storage line, distributed exclusively by ARES Scientific with full warranty support for institutional purchasers across the pharmacy and laboratory refrigerator category.
  • Glass swing door for at-a-glance inventory visibility reduces unnecessary door openings, supports faster visual inventory checks, and preserves cold-chain integrity in high-throughput pharmacy and clinical workflows.
  • Microprocessor temperature controller with digital display manages cycle temperatures between 1°C and 10°C, bracketing the CDC vaccine storage range with precision unavailable from mechanical thermostat designs.
  • Forced-draft air circulation delivers excellent temperature uniformity throughout the cabinet and rapid recovery after door openings — particularly valuable in high-traffic pharmacy environments.
  • Audible and visual high and low temperature alarms with remote alarm contacts integrate with facility BMS or local monitoring stations; a 3/4-inch probe access port accommodates third-party NIST-traceable data loggers.
  • Four adjustable interior shelves and LED interior lighting organize 2.5 cubic feet of storage and support visibility for routine pharmacy and laboratory inventory management.
  • Right-hinged glass swing door with keyed lock balances visibility with sample security and access control documentation requirements in clinical and pharmacy settings — see our vaccine refrigerator selection guide for cold-chain best practices.
  • HFC-free R600a hydrocarbon refrigerant meets sustainability targets and reduces global warming potential versus legacy HFC formulations.
  • UL/C-UL listed and ENERGY STAR certified documents electrical safety compliance and qualifies the unit for institutional energy-efficiency rebate and procurement standardization programs.
  • Two-year parts and labor warranty plus five-year compressor parts warranty; freestanding chassis requires 4 inches of clearance on back and sides for ventilation and warranty compliance.

Frequently Asked Questions – ARS-HC-UCFS-0204G

What is the ARS-HC-UCFS-0204G and how does the glass door affect performance?

The UCFS-0204G is the glass-door variant of the 2.5 cu. ft. ARES Cool Plus Series freestanding countertop laboratory refrigerator. The glass door provides at-a-glance inventory visibility, reducing the number and duration of door openings — a practical benefit for high-throughput pharmacy and clinical workflows. The tradeoff is marginally lower insulation versus the solid-door UCFS-0204, generally offset by reduced cold-air loss from fewer door openings.

When should I choose a glass door over a solid door for vaccine or medication storage?

Glass doors suit pharmacy refrigerators with frequent visual inventory checks, dispensing-room placement where staff need quick stock visibility, and clinical settings where reducing door-open time matters more than maximum insulation. Solid doors better protect light-sensitive contents (certain vaccines like Varicella, some reagents, photoactive medications) — verify the product’s storage requirements before choosing. The CDC Vaccine Storage and Handling Toolkit and our selection guide cover this tradeoff in depth.

Does the UCFS-0204G support CDC vaccine storage requirements?

The microprocessor controller maintains cycle temperatures from 1°C to 10°C, bracketing the 2°C to 8°C CDC vaccine storage window. The unit includes audible and visual alarms plus a probe access port for adding a NIST-traceable data logger or temperature monitoring device — standard CDC requirements. Verify that any light-sensitive products in inventory tolerate glass-door storage; some vaccines explicitly require solid-door units.

What applications use a glass-door undercounter refrigerator?

Common applications include retail and outpatient pharmacy vaccine storage where staff verify inventory visually multiple times per day, reagent storage in research laboratories with frequent retrieval, point-of-use medication storage in clinic exam rooms, and dispensing-room cold storage in hospital pharmacies — anywhere visual inventory verification adds workflow value.

What is the temperature uniformity inside the UCFS-0204G?

Forced-draft air circulation using an interior fan distributes air throughout the cabinet, delivering excellent temperature uniformity and rapid recovery after door openings — performance characteristics that distinguish laboratory and pharmacy refrigerators from household refrigerators that use simpler airflow designs. Exact uniformity figures depend on load configuration and ambient conditions; facility validation testing characterizes specific installations.

Can the glass door be locked?

Yes — the unit ships with a keyed door lock that secures the glass door identically to the solid-door variant, supporting access control documentation for pharmacy and clinical compliance audits under CDC, USP, CAP, CLIA, and institutional QA programs.

Technical Specifications – ARS-HC-UCFS-0204G

SKU: ARS-HC-UCFS-0204G
Storage Capacity: 2.5 cu. ft.
Door: 1 glass swing door, right hinged
Shelves: Four adjustable shelves
Mounting and Installation: Leveling legs
Interior Lighting: LED interior light
Airflow Management: Forced draft air circulation
External Probe Access: Probe access port (3/4 in.)
Insulation: Foamed-in-place EPA-compliant high-density urethane foam
Exterior Materials: White powder-coated steel
Access Control: Keyed door lock
Refrigerant: HFC-free R600a
Defrost: Cycle defrost
Controller Technology: Microprocessor temperature controller
Display Technology: Digital temperature display
Adjustable Cycle Temperature: 1°C to 10°C
External Alarm Connection: Remote alarm contacts
Alarms: Audible and visual high and low temperature alarms
Rated Amperage: 0.9 A
Power Plug/Cord: NEMA 5-15, conforms to UL 471
Facility Electrical Requirement: 115 VAC / 60 Hz / 1 PH
Agency Listing: UL/C-UL listed, ENERGY STAR certified
Exterior Dimensions (W × D × H): 17.75 in. × 19.5 in. × 28.875 in.
Interior Dimensions (W × D × H): 14.25 in. × 13.25 in. × 23.25 in.
Door Swing: 15.5 in.
Total Open Depth: 35 in.
Product Weight: 68 lbs
Shipping Weight: 97 lbs
General Warranty: Two (2) year parts and labor
Compressor Warranty: Five (5) year compressor parts
Operating Environment: Indoor use, +18°C to +26°C (+65°F to +78°F), <70% RH
Installation Note: Freestanding (UCFS) requires 4 in. clearance on back and sides