Hermle-Benchmark Z327-K Refrigerated Universal Centrifuge

Quote

The Hermle-Benchmark Z327-K refrigerated universal centrifuge combines high-speed performance — 18,000 rpm and a maximum RCF of 23,542 × g — with active temperature control from −20°C to +40°C, making it an essential instrument for temperature-sensitive centrifugation workflows across research and clinical laboratories. As part of the universal centrifuge lineup at ARES Scientific, the Z327-K features a rear-mounted refrigeration system that maintains a compact 15.7-inch width, conserving valuable bench space while delivering the cooling power to keep all rotors below 4°C even at maximum speed. With up to 19 interchangeable rotor options — including swing-out rotors for tubes up to 4 × 200 mL, high-speed fixed-angle rotors for microtubes and 50 mL conical tubes, and dedicated microplate rotors — this refrigerated benchtop centrifuge supports applications from enzyme isolation and protein purification to blood component separation and cell culture processing.

The Z327-K refrigerated lab centrifuge is built around a maintenance-free brushless induction drive and advanced microprocessor controls with a large LCD display. Operators can pre-select temperature in 1°C increments and use the Quick-COOL feature to rapidly bring the stainless steel chamber to the target temperature before starting a run. An automatic RFID rotor identification system applies rotor-specific speed limits and activates over-speed protection upon insertion, while active imbalance detection provides rotor-specific cut-off for safe, unattended operation. With up to 99 programmable protocols, 10 selectable acceleration and deceleration rates, and a timer extending to 99 hours and 59 minutes with continuous-run capability, the Z327-K gives operators precise control over every centrifugation parameter. Browse the full selection of laboratory centrifuges at ARES Scientific to compare refrigerated and non-refrigerated models for your specific throughput needs.

Manufactured by Benchmark Scientific in collaboration with Hermle Labortechnik, the Z327-K refrigerated centrifuge operates below 63 dBA at maximum speed and complies with IEC 61010 international safety standards. Its CFC-free refrigeration system and motor-driven lid lock make it well suited for shared laboratories, blood bank processing facilities, and clinical environments that demand both performance and regulatory compliance. Pair the Z327-K with complementary benchtop instruments such as homogenizers and vortex mixers to build a complete temperature-controlled sample preparation workflow. ARES Scientific is an authorized distributor for Benchmark Scientific, ensuring you receive a genuine Hermle Z327-K with full manufacturer warranty and dedicated technical support.

Description

Hermle-Benchmark Z327-K Refrigerated Universal Centrifuge – Product Highlights

  • Active refrigeration from −20°C to +40°C — pre-select chamber temperature in 1°C increments to protect heat-sensitive samples such as enzymes, proteins, nucleic acids, and blood components during high-speed centrifugation.
  • Quick-COOL rapid pre-cooling function — brings the stainless steel chamber to the target temperature at the touch of a button, reducing wait times and keeping workflows on schedule.
  • Maximum RCF of 23,542 × g at 18,000 rpm — delivers the centrifugal force required for demanding separations including cell pelleting, subcellular fractionation, nucleic acid isolation, and gradient purification in research and clinical settings.
  • Up to 19 interchangeable rotor options — choose from swing-out, fixed-angle, high-volume, and microplate rotors to process tubes from 0.2 mL microtubes up to 200 mL bottles, deepwell plates, and standard blood bank collection tubes on a single platform.
  • Space-saving rear-mounted refrigeration — the cooling system is integrated behind the unit, keeping the footprint to just 15.7 inches wide so the Z327-K fits on standard laboratory benches alongside other centrifuge and sample preparation equipment.
  • Automatic RFID rotor identification with over-speed protection — recognizes each rotor upon insertion and enforces rotor-specific speed limits, preventing operator error and safeguarding samples from excessive g-force.
  • 99 programmable protocols with extended timer — store and recall user-defined run parameters including temperature, speed, and duration for one-touch operation, with timer capability up to 99 hours and 59 minutes plus continuous-run mode for overnight separations.
  • Motor-driven lid lock and active imbalance detection — automatic lid lock prevents opening during operation, while rotor-specific imbalance monitoring stops the run if load asymmetry is detected, protecting both the instrument and valuable samples.
  • Quiet operation under 63 dBA with IEC 61010 compliance — the maintenance-free brushless induction drive and CFC-free refrigeration system operate below conversational noise levels, meeting international safety standards for clinical and shared laboratory environments.
  • Authorized Benchmark Scientific distributor — ARES Scientific is an authorized distributor for Benchmark Scientific, ensuring you receive a genuine Hermle Z327-K refrigerated centrifuge backed by full manufacturer warranty, technical support, and access to the complete range of compatible rotors and accessories.

Technical Specifications – Benchmark Scientific Hermle Z327-K

Model Number: Z327-K (120V) / Z327-K-E (230V)
SKU: Z327-K
Speed Range: 200 – 18,000 rpm
Maximum RCF: 23,542 × g
Maximum Capacity: 4 × 200 mL (swing-out rotor)
Temperature Range: −20°C to +40°C (1°C increments)
Pre-Cooling: Quick-COOL rapid chamber pre-cooling function
Refrigerant: CFC-free
Rotor Options: Up to 19 — swing-out, fixed-angle, high-volume, and microplate rotors (sold separately)
Tube Compatibility: 0.2 mL to 200 mL tubes, blood collection tubes, 15 mL and 50 mL conical tubes, microtubes (1.5/2.0 mL), microplates, deepwell plates
Timer: Up to 99 hr 59 min and continuous
Programmable Protocols: Up to 99
Acceleration/Deceleration Rates: 10 acceleration / 10 deceleration profiles
Rotor Identification: Automatic RFID with over-speed protection
Imbalance Detection: Active imbalance identification and rotor-specific cut-off
Lid Lock: Motor-driven automatic lid lock
Chamber: Stainless steel with active refrigeration
Display: Large LCD microprocessor display
Drive: Maintenance-free brushless induction motor
Noise Level: < 63 dBA at maximum speed
Dimensions (W × D × H): 15.7 × 27.5 × 14 in. (40 × 70 × 36 cm)
Weight: 132 lbs (60 kg)
Electrical Requirements: 120V, 50–60 Hz (Z327-K) / 230V, 50–60 Hz (Z327-K-E)
Certifications: IEC 61010
Non-Refrigerated Model Available: Z327 (120V) / Z327-E (230V)